Bringing doctors together

or

A free, private network for verified physicians

Leading voices

Dr. Nishant Shah

Preventive Cardiology · Duke Hospital

View

Dr. Amit Khera

Preventive Cardiology · UT Southwestern

View

Dr. Martha Gulati

Preventive Cardiology · Houston Methodist

View

Dr. Pradeep Natarajan

Preventive Cardiology · MGH

View

Dr. Christopher Cannon

Preventive Cardiology · BWH

View

Dr. Dorairaj Prabhakaran

General Cardiology

View

Dr. Pugazhendhi Vijayaraman

EP · Geisinger

View

Dr. Robert Schaller

EP · HUP

View

Dr. Trey Woods

General Cardiology · Emory Healthcare

View

Dr. Brahmajee Nallamothu

Interventional Cardiology · UMHS

View
  • Discover your community

  • Stay current

  • A profile that represents you

  • Find your people

About RoonPrivacyTerms

    Overview

    Detection of Hypertrophic Cardiomyopathy on Electrocardiogram Using Artificial Intelligence.

    May 14, 2025DOI: 10.1161/circheartfailure.124.012667Journal ArticleAHA

    Written by: James M HillisBernardo C BizzoSarah F MercaldoAnkita GhatakAshley L MacDonaldMadeleine A HalleAlexander S SchultzEric L'ItalienVictor TamNicole K BartFilipe A MouraAmine AwadDavid BargielaSarajune DagenDanielle TolandAlexander J BloodDavid A GrossKarola S JeringMathew S LopesNicholas A MarstonVictor D NauffalKeith J DreyerBenjamin M SciricaCarolyn Y Ho

    Find these authors on Roon

    FM

    Dr. Filipe Moura

    Advanced Cardiac Imaging · Yale College

    NM

    Dr. Nicholas Marston

    Preventive Cardiology · BWH

    Summary

    BACKGROUND: Hypertrophic cardiomyopathy (HCM) is associated with significant morbidity and mortality, including sudden cardiac death in the young. Its prevalence is estimated to be 1 in 500, although many people are undiagnosed. The ability to screen electrocardiograms for its presence could improve detection and enable earlier diagnosis. This study evaluated the accuracy of an artificial intelligence device (Viz HCM) in detecting HCM based on a 12-lead electrocardiogram.METHODS: The device was previously trained using deep learning and provides a binary outcome (HCM suspected or not suspected). This study included 293 HCM-positive and 2912 HCM-negative cases, which were selected from 3 hospitals based on chart review incorporating billing diagnostic codes, cardiac imaging, and electrocardiogram features. The device produced an output for 291 (99.3%) HCM-positive and 2905 (99.8%) HCM-negative cases.RESULTS: The device identified HCM with sensitivity of 68.4% (95% CI, 62.8-73.5%), specificity of 99.1% (95% CI, 98.7-99.4%), and area under the curve of 0.975 (95% CI, 0.965-0.982). With assumed population prevalence of 0.002 (1 in 500), the positive predictive value was 13.7% (95% CI, 10.1-19.9%) and the negative predictive value was 99.9% (95% CI, 99.9-99.9%). The device demonstrated broadly consistent performance across demographic and technical subgroups.CONCLUSIONS: The device identified HCM based on a 12-lead electrocardiogram with good performance. Coupled with clinical expertise, it has the potential to augment HCM detection and diagnosis.
    NMDr. Nicholas Marston
    Leading Voice

    Dr. Nicholas Marston

    Cardiology · Preventive Cardiology
    Brigham and Women's Hospital
    nicholas