Bringing doctors together

or

A free, private network for verified physicians

Leading voices

Dr. Ram Vaidhyanath

Neuroradiology

View

Dr. Judith Gadde

Neuroradiology · Lurie Children's Hospital

View

Dr. Wende Gibbs

Neuroradiology · Barrow Neurological Institute

View

Dr. Daniel Gewolb

Neuroradiology · University of Miami

View

Dr. Sumir Patel

Neuroradiology · Emory University

View

Dr. Julie Bulman

Interventional Radiology · BIDMC

View

Dr. Monica Sheth

Breast Imaging · NYU Langone

View

Dr. Victoria Chernyak

Abdominal Imaging · CUIMC

View

Dr. Laura Hayes

Peds Radiology · Children's Healthcare of Atlanta

View

Dr. Amy Patel

Breast Imaging · UKHS

View
  • Discover your community

  • Stay current

  • A profile that represents you

  • Find your people

About RoonPrivacyTerms

    Overview

    Diagnostic Accuracy of Portable Low- and Ultra-Low-Field MRI for Acute Ischemic Stroke: A Systematic Review and Meta-Analysis.

    Jul 16, 2026DOI: 10.3174/ajnr.a9532Journal ArticleAJNR

    Written by: Mehmet Can PenceAlperen ElekCem BilginSedat Giray KandemirliHasan BaniHaniRam KadirvelIan T MarkJohn C BensonGirish BathlaWaleed BrinjikjiDavid F Kallmes

    Find these authors on Roon

    SK
    Dr. Sedat Kandemirli
    Neuroradiology · Boston Children's Hospital

    Summary

    BACKGROUND: Portable low-field and ultra-low-field MRI enables bedside imaging, but its diagnostic performance for acute ischemic stroke (AIS) detection remains uncertain.PURPOSE: To evaluate the diagnostic performance of portable MRI for AIS detection.DATA SOURCES: Four databases were searched on February 2, 2026.STUDY SELECTION: Eligible studies enrolled adults with suspected or confirmed AIS undergoing portable MRI. Nine studies comprising 474 patients with AIS were included.DATA ANALYSIS: In studies with an appropriate reference standard, pooled sensitivity and specificity were synthesized using a bivariate random-effects model, and a hierarchical summary receiver operating characteristic curve was generated. Across all eligible AIS cohorts, the pooled lesion detection rate was estimated using a generalized linear mixed-effects model with random effects.DATA SYNTHESIS: In six comparative studies, the pooled sensitivity for AIS detection was 73.3% (95% CI, 65.4-80.0), corresponding to approximately one in four confirmed infarcts being missed, with missed lesions generally small or sub-centimetric. Pooled specificity was 79.3% (95% CI, 69.1-86.8), and the area under the curve was 0.818. The pooled AIS lesion detection rate was 87.65% (95% CI, 75.7-94.2).LIMITATIONS: There was substantial between-study heterogeneity (I2 = 74.2%). This estimate was interpreted as secondary and descriptive because it included case-only confirmed AIS cohorts.CONCLUSIONS: Portable low/ultra-low-field MRI showed moderate diagnostic performance for AIS detection in comparative studies and may serve as a bedside adjunct where conventional MRI is constrained. However, given the false-negative risk, portable MRI should not be relied upon as a stand-alone rule-out test for AIS when clinical suspicion persists.
    SKDr. Sedat Kandemirli

    Dr. Sedat Kandemirli

    Radiology · Neuroradiology
    Boston Children's Hospital
    sedat